■VSWR METER
The VSWR Meter detects Pf(Forward) and Pr(Refrect) monitor signals inputted from up to four directional couplers, and then A/D-converts, corrects and calculates them so that the meter shows Forward power, Reflect power and VSWR on the monitor.
The offset values of the coupling factor of the directional couplers, the loss of the coaxial cable can be set as needed. As thresholds of the each display values can be set, the Meter can generate an alarm signal when an anomaly occures.


Model A170-30CCA
Input frequency 1.3GHz±10MHz
Input impedance 50Ω (VSWR1.2 or less)
Proper RF input level Up to +20dBm
Non-damaged input level +24dBm
Input points 4 points incident wave, 4 points feflected wave
Input connector SMA-FEMALE
Pf,Pr full scale 0 to 999 (By the offset setting, decimal point position and different units)
Pf,Pr power detection accuracy Less than ±2% of full scale
Pf, Pr offset 20.0 to 79.9dB
VSWR full scale 1.00 to 9.99
VSWR detection sccurary Less than ±0.02
Alarm setting Pf,Pr: 0 to 999(By the offset setting, decimal point position and different units)
VSWR: 1.00 to 9.99
Alarm response time Pf,Pr: Less than 1µs
VSWR: Less than 5µs
Power supply AC100V
Size 480(W)x132.6(H)x550(D) (mm)