■RF Power Generator   H series   13.56/27.12/40.68/60.00MHz
      With attached automatic impedance matching box
Applications for RF Power Generator include induction heating, RF plasma, ultrasonic cleaning, metal/plastic welding and fabrication, chemical analysis, medical thermal therapy, and in oscillator units for accelerators. Various industrial fields need RF Power Generator.
THAMWAY's RF Power Generator has excellent stability of frequency and power output. Our Power Generator is very reliable and will not malfunction under assumed load conditions. THAMWAY guarantees trouble-free operation.
THAMWAY's H Series RF Power Generator has output frequencies of 13.56MHz, 27.12MHz, 40.68MHz, or 60.00MHz. There are various power output levels available for the products.
The H Series comes with an impedance matching box which performs the matching process manually or automatically.
We design and developed H Series for its compactness and low cost.
We provide the unit case to your preference.

■Features
Solid state power generator
13.56MHz/27.12MHz
 /40.68MHz/60.00MHz
CW / PULSE Operation
 ※Option:Pulser built in
 ※ON/OFF time 50μ - 10ms
Attached matching box
Preset function
Power meter (Digital)
High stability (Crystal oscillator)
Compact
Low price
HA:Forced air cooling
HW:Water cooling

■Control signal (Example)
RF ON/OFF
Output power setting
Progressive wave
  / Reflected wave monitor
Vdc・Vpp monitor
External interlock
Master / Slave
Various abnormal status   etc.

▲T161-5713HA

▲Matching Box (5kW)

□Example of the RF Power Generator specifications
Frequency 13.56MHz/27.12MHz/40.68MHz/60.00MHz *Which one
Frequency Stability Less than ±0.05%
Oscillation Method Crystal oscillator
Output Power Stability Less than ±1%
Sprious Less than -40dB
Output Impedance 50Ω
Monitor Output Pf monitor (0 to Output power/0 to +10V)
Pr monitor (0 to Reflective power/0 to +10V)
Protective Function Excessive reflection (Less than 25%)
DC supply failure
Abnormal temperature
External interlock
Output Connector N,HN,LC-FEMALE etc.
Power Supply AC100V/AC187 - 230V 1φ/3φ 50Hz/60Hz
Cooling Method HA: Forced air cooling
HW: Water cooling (Some forced air)

□Model list of H series
Model Output power Size(mm)
T161-50◆◆HA100W 480(W)x149(H)x450(D)
T161-55◆◆HA 300W
T161-57◆◆HA 500W
T161-60◆◆HA 1kW480(W)x249(H)x550(D)
T161-63◆◆HA 2kW
T161-65◆◆HW 3kW480(W)x199(H)x550(D)
T161-67◆◆HW 5kW480(W)x399(H)x550(D)
T161-70◆◆HW 10kW To be reviewed
T161-72◆◆HW 15kW
◆◆ Following frequency number according to the output frequency

Frequency Frequency number
13.56MHz 13
27.12MHz 27
40.68MHz 40
60.00MHz 60

□Example of the Matching Box specifications
Matching range 2.7Ω - 42Ω: Standard (TBD)
Output Connector Copper plate (TBD)