Sorry SOLD OUT
HF Linear Amplifier
DXV500L+4
Model | DXV500L+4 |
Frequency |
1.8MHz Band | 1,800 - 2,000kHz |
3.5MHz Band | 3,500 - 4,000kHz |
7 - 10MHz Band | 7,000 - 10,150kHz |
14 - 21MHz Band | 14,000 - 21,450kHz |
*It changes with the rotary switch that exists in the front panel. |
|
Output Power |
1.8 - 7MHz | 500W |
10 - 18MHz | More than 350W |
21MHz - | More than 300W |
|
Harmonic Distortion | Less than -50dB (Each Band/In the rated power in 50Ω load) |
3rd IMD | Less than -25dB (Each Band/In the rated power) |
Drive Power | 25 - 50W (Each Band/In the rated power) |
Final Device | 2SK2482x6 (3 Parallel Push-Pull) |
Final Input | 125V,6A 750W(7MHz at 500W) (50Ω load operated by AC 100V) |
I/O Connector | M-Female |
T/R Control | Receive:H Transmit:L |
Break-in | Semi Break-in |
Cooling | Forced Air The cooler fan starts rotating at 40℃ of the heat sink. |
Monitor Circuits | Analog meter display
FWD Power,REV Power
Final Drain Voltage,Final Drain Current
*It selects it with the rotary switch of the front panel. |
ALC | -4V@500W |
Protection Circuits |
REV Power Protection | When the REV power Amplifier becomes about 50W,the amplifier is turned off. |
Over Current Protection | When the drain current becomes about 6.2A, the amplifier is turned off. |
Over Temperature Protection | When the temperature of the heat sink becomes about 100℃, the amplifier is turned off. |
Protection circuit reset | A linear ON switch is turned off once, and it turned on again afterwards. |
Over Input Protection | Please use ALC. |
|
Power Supply | AC100 - 120V 1kVA(Max Power) |
Size | (W):202mm (H):101mm (D):303mm (excluding protrusions) |
Weight | less than 5.0kg |
Accessories |
AC power cable (AC100V for domestic use. 1.8m) | 1 |
SEND/ALC cable(1m) | 1 |
User Manual | 1 |
|
All stated specifications are typical and subject to change without notice or obligation.
Back
|
|